EasyManuals Logo

Festo CMMS-AS-C4-3A User Manual

Festo CMMS-AS-C4-3A
123 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #43 background imageLoading...
Page #43 background image
3. Product description
Festo P.BE-CMMS-AS-HW-EN en 0708NH 43
Required I/O connection for field bus control
The connection plan shows the switch position in the active operating state.
*) The limit switches are set by default to opener (configuration over FCT)
3.4.1 FHPP
FHPP makes it possible to achieve a uniform control concept regardless of the field bus
used. The user therefore no longer be concerned with the specific characteristics of the
respective busses or controllers (PLC), but receives a preparameterized profile in order to
place his drive into operation in the shortest possible time and control it.
Among the operation types, FHPP distinguishes between record selection and direct opera-
tion.
With record selection, the position records stored in the controller are used.
In direct operation,
the positioning mode,
speed control or
force control
can be employed.
These can be dynamically switched over in direct operation as needed.
Additional information can be found in the FHPP manual P.BE−CMM−FHPP−SW−EN.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Festo CMMS-AS-C4-3A and is the answer not in the manual?

Festo CMMS-AS-C4-3A Specifications

General IconGeneral
BrandFesto
ModelCMMS-AS-C4-3A
CategoryController
LanguageEnglish

Related product manuals