The sequence in Tab.2/6 applies for addressing.
Module
no.
Module Addressing
Input address Output address
0 Field bus node CPX−FB11
1 Digital 8−input module CPX−8DE I1.3.0 ... I1.3.7
2 Digital 4−output module CPX−4DA O1.9.0 ... O1.9.7
*)
3 CP interface
CP I, here: 4 bytes I, 16 bytes O
I1.1.0 ... I1.1.7
I1.1.8 ... I1.1.15
I1.2.0 ... I1.2.7
I1.2.8 ... I1.2.15
O1.1.0 ... O1.1.7
O1.1.8 ... O1.1.15
O1.2.0 ... O1.2.7
O1.2.8 ... O1.2.15
O1.3.0 ... O1.3.7
O1.3.8 ... O1.3.15
O1.4.0 ... O1.4.7
O1.4.8 ... O1.4.15
O1.5.0 ... O1.5.7
O1.5.8 ... O1.5.15
O1.6.0 ... O1.6.7
O1.6.8 ... O1.6.15
O1.7.0 ... O1.7.7
O1.7.8 ... O1.7.15
O1.8.0 ... O1.8.7
O1.8.8 ... O1.8.15
4 Digital multi I/O module
CPX−8DE−8DA
I1.3.7 ... 1.3.15 O1.9.8 ... O1.9.15
5 MPA1 pneumatic module (8DO) O1.10.0 ... O1.10.7
6 MPA1 pneumatic module (8DO) O1.10.8 ... O1.10.15
*)
8 bits occupied, 4 bits used
Tab.2/16: Addressing for scanner 1747−SDN with CPX example terminal 2 (seeFig.2/2)
with modular EDS