6.3 Possible EST error messages, their cause and suggested action
The communication adapter was unable to connect to the J1939 data link.
Cause: EST was unable to see the Communication adaptor on the port it is expecting it to be connected to
Ensure that Communication adapter is connected to the PowerWizard panel and has power•
Ensure that the communication adapter is connected to the PC•
Ensure that the settings on the service tool are set for the correct port•
Ensure that the communication adapter is using RP1210 (under utilities -> preferences -> communications)•
“No ECMs detected”
Cause: EST was unable to detect any PowerWizard modules on the J1939 network.
Ensure the PowerWizard module is powered up and is not in Reduced Power Mode•
Check the J1939 wiring between the PowerWizard and the communications adapter, particularly the termination •
resistor(s).
The ECM software le and the ECM are not compatible. Process aborted. - Error Code: 163840”
Cause: The ash le is not compatible with the PowerWizard. This is usually seen when trying to ash a module with software for a
dierent module, such as trying to ash a PW1.1 with a ash le for a PW1.1+ or 2.1.
Use a flash file that is compatible with the level of PowerWizard control you are trying to flash.•
“No ash le selected for the ECM”
Cause: This error message is seen when trying to use a ash le that is not suitable for any level of PowerWizard control.
Use a flash file that is compatible with the level of PowerWizard control you are trying to flash.•