EasyManuals Logo

Fibocom MC610 Series User Manual

Fibocom MC610 Series
70 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #59 background imageLoading...
Page #59 background image
Reproduction forbidden without Fibocom Wireless Inc. written authorization - All rights reserved.
FIBOCOM MC610 Series Hardware Guide 59/70
5.3 Electrical Characteristics of Interface Working State
V
L
: logic low level;
V
H
: logic high level;
Table 5-3 IO Interface level
Level
Signal
VL
VH
Unit
Min
Max
Min
Max
1.8 V
Digital input I
-
0.54
1.26
2.0
V
Digital output O
-
0.36
1.44
-
V
3V
Digital input I
-
0.45
2.1
3.2
V
Digital output O
-
0.45
2.1
-
V
Table 5-4 Power Interface level
Parameter
I/O
Min
Typ
Max
Unit
VBAT
I
3.4
3.8
4.2
V
SIM_VCC
O
1.7/2.75
1.8/2.85
1.9/2.95
V
5.4 Environment and Reliability Requirements
Table 5-5 Environmental reliability
Test Item
Test Condition
Low-temperature storage test
The temperature Is - 45 °C ± 3 °C, and the Power OFF state lasts
for 24 hours
High-temperature and
low-temperature storage test
The temperature Is +90 ± 3°C, and the Power OFF state lasts for
24 ours
Temperature impact test
In the Power OFF state, 24 cycles shall be carried out under -

Questions and Answers: