16
LOADING PROCEDURE
Take care not to lose pens, lighters, etc. from shirt pockets, or drop
pieces of paper or plastic bags into the tank, as these might plug the
slurry system. Failure to comply could result in death or serious injury. Failure to comply
could also result in product or property damage.
1. With the slurry pump clutch disengaged (turned off) and the agitator control lever in
the NEUTRAL position, start the engine and allow it to warm up for 3 to 5 minutes (see
STARTING PROCEDURE).
2. Start filling unit with water from one of the water sources as listed below. When water
reaches the top of agitator shaft, move agitator control lever to full REVERSE position.
Tank can be filled by using one of the sources of water as follows:
A. Water from any stream or pond using a fill transfer pump. When filling from a pond
or stream, be sure to use a suction strainer to filter out contaminants that could
damage the pump and unit.
B. Any pressure source, eg. fire hydrant. An optional air gap fill port is available for
this unit but it is necessary to consult with local authorities before using a water
main, in order to abide by all local ordinances.
C. Water tanker.
3. Piping System Cleanout Procedure (Purging Line):
A. Remove discharge nozzle and coupler gasket from the remote valve coupler at the
end of the discharge hose or from boom.
B. Aim discharge hose or boom into an open area away from any persons,
obstructions, or high voltage power lines.
C. Open discharge and / or remote valve and close recirculation valve.
D. With the engine at low idle, turn on / engage the slurry pump.
E. Increase the engine RPMs to between 1/2 to 3/4 throttle.
F. When discharge stream is clear, open recirculation valve and close discharge
and / or remote valve. After recirculation stream is clear, disengage (turn off) the
slurry pump.
G. Replace coupler gasket in the remote valve coupler.
4. Continue filling tank with water.
5. Increase engine speed to full RPM.