421827
62
8.21 Removal of Pump
Note: Approximately 250mls of water remains in the pump sump after pump out and will
spill when the pump is removed. Take care not to spill this water over electrical
connections by using a towel or small container to catch the water
8.21.1 Selni
(a) Tilt the rear of the machine carefully against
the wall ensuring that the machine is stable
and locked in position; take necessary
precautions not to damage the wall or the
machine.
(b) Remove the wiring harness and earth wire
to the pump.
(c) Release the locking tab by pulling it away
from the pump. Keep pressure on the tab
and turn the body of the pump in an counter-
clockwise direction. Continue to turn until
the pump disengages.
Locking Tab
.
Reassembly:
(a) Lubricate the seal face with liquid soap or detergent (do not use grease).
(b) Locate the bayonet fixture correctly, and then turn the pump in a clockwise direction until you
hear the locking tab clicks into place.
(c) Connect the earth wire ensuring that the tab is locked into place by applying gentle pressure on
the wire.
(d) Connect main harness. Ensure that the wiring is routed correctly and will not foul on any
moving components.