Lit. No. 44224, Rev. 14 105 August 15, 2011
MAINTENANCE
Use the following procedure to install
hydraulic hoses:
1. Screw the are nut onto the tting are and
hand tighten.
2. Align the hose so there are no twists or sharp
bends and so it will not be pinched or pulled
by moving parts.
3. Using two wrenches, hold the hose in position
and tighten the are nut 1/81/4 turn beyond
hand tight. Final torque on the are nut should
be approximately 20 ft-lb.
4. Reinstall any protective hose wraps in their
original positions.
FUSE REPLACEMENT
The vehicle electrical system contains several
automotive blade-style fuses. The snowplow
park/turn and control power is covered by fuses in
the under hood snowplow wiring. The control fuse
is "hot" when the vehicle ignition switch is ON and
the electrical connections to the snowplow are
completed.
See the Harness Diagram applicable to the
electrical system on your snowplow at the end of
this manual for fuse ratings and locations.
The XtremeV™ hydraulic unit harness system
contains four automotive blade-style mini fuses.
The 3-solenoid harness (to Port B on the hydraulic
unit module) and 8-solenoid harness (to Port C)
each contain two 4-amp mini fuses.
The XLS™ hydraulic unit harness system contains
four automotive blade-style mini fuses. The
2-solenoid harness (to Port B on the hydraulic unit
module) and 6-solenoid harness (to Port C) each
contain two 4-amp mini fuses.

Table of Contents