Lit. No. 44224, Rev. 14 100 August 15, 2011
NOTE: On XtremeV™ and XLS™ blades, add
uid only when all rams are retracted.
10. For straight blades, any angle will do, but
XtremeV and XLS blades must be in fully
retracted (vee) position. With the lift ram fully
retracted, ll the reservoir with FISHER
®
EZ Flow hydraulic uid to –40°F (–40°C), or
other uid conforming to Military Speci cation
MIL-H-5606A, such as Mobil Aero HFA or
Shell AeroShell
®
Fluid 4. Replace the ll plug.
CAUTION
Do not raise blade during ll process as
this may cause pump cavitation.
AeroShell
®
is a registered trademark (
®
) of Shell Oil Company.
Air Removal – HT Series™ and Straight Blades
11. Turn the control ON and completely angle the
blade to the left and right several times. Turn
the control OFF.
12. Fill the reservoir to the top of the ll hole and
replace the ll plug.
NOTE: Loosen ll plug slowly to relieve any
pressure in the reservoir.
13. Turn the control ON and raise and lower the
snowplow several times. Activate the control
FLOAT function and manually collapse the lift
ram all the way (not required for HT Series
blades) after each lowering of the blade. Turn
the control OFF.