Lit. No. 44224, Rev. 14 38 August 15, 2011
STRAIGHT BLADE
OPERATING YOUR SNOWPLOW
Automatic Shutdown
The control will automatically turn OFF after being
idle for 20 minutes. To reactivate the control after
a shutdown, press the ON/OFF button.
Smooth Stop
The control automatically allows the blade to coast
to a stop when the button is released. This results
in smoother operation, reduces the shock to the
hydraulic system and increases hose and valve life.
Control Functions
Raise, Lower, Float, Angle
The four triangle-shaped buttons in the center of
the control face, when pressed, will result in the
blade movements described in the table.
NOTE: If control function times out before
desired blade movement is complete, release
button and press again.
Function Description of Operation
ON/OFF
Press this button to turn the control ON and
OFF. Turn the control OFF (power indicator
light OFF) to lock the blade in place. This
prevents accidental movement of the blade.
RAISE
Press this button to raise the snowplow and
to cancel FLOAT mode. Function times out
after 4.8 seconds.
LOWER
Press this button to lower the snowplow.
Release button to stop blade at desired height.
FLOAT
Press LOWER button and hold for 3/4 second
to activate this mode. FLOAT light in upper
left corner of control face will illuminate.
Blade will lower to ground surface and
follow contour of surface as it dips or raises.
Function does not time out; however, control
will shut down after 20 minutes of nonuse.
Press RAISE button momentarily to cancel
FLOAT. Angling left or right will interrupt (stop)
the FLOAT function, but FLOAT will resume
when angling is complete.
LEFT
Press this button to angle the blade to the left.
Function times out after 9.6 seconds.
RIGHT
Press this button to angle the blade to the
right. Function times out after 9.6 seconds.