Lit. No. 44224, Rev. 14 95 August 15, 2011
MAINTENANCE
Fill
Plug
Drain
Cap
XLS BladesXtremeV Blades
Drain
Cap
Fill
Plug
Fill
Plug
Drain
Plug
Straight Blades
XtremeV™, XLS™ and other Straight Blades:
With the Minute Mount
®
2 system attached to the
vehicle, activate the control. For straight blades,
any angle will do, but for XtremeV and XLS
blades, move blade wings to the fully retracted
(vee) position. Activate the control FLOAT function
and manually collapse the lift ram all the way.
Turn the control OFF. Remove the fi ll plug. Fill the
reservoir to the top of the fi ll hole and replace the
fi ll plug.
For fl uid recommendations see the following
Annual Fluid Change section.