Lit. No. 44224, Rev. 14 71 August 15, 2011
OPERATING YOUR SNOWPLOW
Fluid Level
With Minute Mount
®
2 system attached to the
vehicle, activate the control. For straight blades,
any angle will do, but for XtremeV™ and XLS
blades, move blade wings to fully retracted (vee)
position. Then, for all blades, activate the control
FLOAT function and manually collapse the lift ram
all the way. Turn the control OFF. Remove the ll
plug.
HT Series™ Blades: Fill the reservoir to within
2-1/2" from the top of the ll hole and replace the
ll plug.
XtremeV, XLS and other Straight Blades: Fill
the reservoir to the top of the ll hole and replace
the ll plug.
For hydraulic uid type and lling instructions, see
Hydraulic System, Annual Fluid Change, in the
Maintenance section of this manual.
XLS™ Blades
Breather
Quill
Reservoi
r
Valve
Manifold
Motor
Drain
Cap
Fill
Plug
Motor
Relay
set limits, the relief valve opens allowing uid to
escape and the ram retracts.