8 - ADVANCED PROGRAMMING MODE
6700 / 6765
8.10. Display format (U)
Ex.: - US format (gallon) [U - - - - 1]
- Litre format [U - - - - 2]
- Standard metric [U - - - - 3]
- Cubic meter format [U - - - - 4]
Note: if this parameter is changed, the programming comes
immediately back to the level 1 and directly followed by the level 2.
8.11. Valve type (o)
Ex.: 6700 [o - - - - 2]
8.12. Regeneration type (7)
Ex.: - Timeclock [7 - - - - 1]
- Meter immediate [7 - - - - 2]
- Meter delayed [7 - - - - 3]
- 6 cycles mode [7 - - - - 7]
8.13. Flow meter size (F)
Ex.: - Standard 3/8’’ [F - - - - 0]
- Standard 3/4’’ [F - - - - 1]
8.14 Mixing valve location (8)
Ex.: - No mixing valve [8 - - - - 1]
- Mixing valve before flow meter [8 - - - - 2]
- Mixing valve after flow meter [8 - - - - 3]
8.15. System type (9)
Ex.: System #4-One alone electronic [9 - - - - 4]
8.16. Program lockout (PL)
Ex.: - Cancelled lockout [PL- -OFF]
- Lockout active [PL - - On]
Advanced programming mode exit.
The valve returns in normal operation
Note :
1. Push the button once
per display.
2. Option settings may be
changed by pushing the
and set buttons