EasyManuals Logo

Fleck 9500 Service Manual

Fleck 9500
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #7 background imageLoading...
Page #7 background image
Printed in U.S.A.
Page 7
MODEL 9500 ECONOMINDER
Time Brine Refill & Meter Setting Procedure (Cont’d.)
If we have 4800 gallons available from Step 3, we want to subtract the regeneration water used from the total water
available.
4800 gallons available - 342 gallons used (in regeneration, step 4) = 4458 gallons setting
5. NOW set Meter wheel at approximately 4458 gallons. Lift the inner dial of the meter program wheel so that you can
rotate it freely. Position the white dot opposite the 4458 gallon setting (see diag. below).
NOTE: There is a slight delay time from the time the meter zeros out and when the cycle starts. Units using the 1/15
rpm motor, 82 minute regeneration time available have a 9 minute delay. Units using the 1/30 rpm motor,
180 minute regeneration time available have an 18 minute delay. Typically on residential equipment this
delay period is not critical. On commercial applications, this must be taken into consideration and
continuous flows for 9 minutes or 18 minutes should be subtracted from water available.
NOW 1. Insert Meter cable into Meter.
2. Check Bypass.
3. Plug unit in.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fleck 9500 and is the answer not in the manual?

Fleck 9500 Specifications

General IconGeneral
BrandFleck
Model9500
CategoryControl Unit
LanguageEnglish

Related product manuals