7 Installation of FLUXUS G801 FLUXUS G80x
UMFLUXUS_G8V4-6-1EN, 2018-10-10 47
passive current 
loop/HART
G801**-A10****-*P
current loop 
I1/I2: 1/3 (-)
I1/I2: 2/4 (+)
U
ext
 =
 
4...26.4 V
U
ext
 > 0.021 A 
. 
R
ext
 [Ω] + 4 V
example:
U
ext
 = 12 V
R
ext
 = 0…380 Ω
current during transmitter error:
I
fault
 ≈ 0 mA
HART mode
I1: 1 (-)
I1: 2 (+)
U
int
 = 24 V
current during transmitter error:
I
fault
 ≈ 0 mA
frequency output 
(open collector)
G801**-A10****-FF
F1: 2 (+)
F1: 1 (-)
U
ext 
= 5...30 V
R
c
 [kΩ] = U
ext
/I
c
 [mA]
I
c
 = 2...100 mA
I
off
 = 0.8 mA
frequency output
(open collector)
G801**-A10****-FF
F1: 2 (+)
F1: 1 (-)
U
ext 
= 8.2 V
R
c
 = 1 kΩ
DIN EN 60947-5-6
(NAMUR)
binary output
(open collector)
G801**-A10****-FF
B1: 6 (+)
B1: 5 (-)
U
ext 
= 5...30 V
R
c
 [kΩ] = U
ext
/I
c
 [mA]
I
c
 = 2...100 mA
I
off
 = 0.8 mA
binary output 
(open collector)
G801**-A10****-*A
G801**-A10****-*P
B1...B4:
6/8/10/12 (+)
B1...B4:
5/7/9/11 (-)
U
ext 
= 5...24 V
R
c
 [kΩ] = U
ext
/I
c
 [mA]
I
c
 = 1...4 mA
binary output 
(Reed relay)
G801**-A10****-*A
G801**-A10****-*P
B3/B4: 9/11
B3/B4: 10/12
U
max
 = 48 V
I
max
 = 100 mA
Tab. 7.7: Circuits of the outputs 
output transmitter external circuit remark 
internal circuit  connection 
The number, type and connections of the outputs are customized.
R
ext
 is the sum of all ohmic resistances in the circuit (e.g., resistance of the conductors, resistance of the amperemeter/voltmeter).
ƒ
G