FT-112(D) Panel Weighing Indicator, Technical Manual, Rev.1.0.0, May 2019 Page 39 of 170
Access to Alibi records:
1. Go to the parameter [ 8-- METROLOGY] main block in set up.
2. Press key 4 times to access parameter 813.
3. Select the suitable criteria by pressing or keys which are NUM (Alibi number),
DATE (weighing date), NET (net weight), GROS (gross weight), TARE (tare weight) or
CN (consecutive number).
Alibi records will be displayed in sequence:
1. Alibi record number
2. Date
3. Time
4. Gross weight
5. Net weight
6. Tare weight
7. Consecutive number
Search with Alibi record number:
1. Press key after selecting NUM in parameter 813.
2. Press numerical keys to enter alibi number in the printout data and press key. You
may navigate in the alibi memory with or keys after entering alibi number.
3. The weighing data in the alibi memory is indicated on the display.
4. Press key to print this record and the previous nine weighing.
5. Press key 4 times to return operation.
Search with date:
1. Press key after selecting DATE in parameter 813.
2. Press numerical keys to enter date in the printout data and press key. The date
format entry should be as in the operation. e.g. date entry should be DDMMYY if
parameter 251 is set to DMY. You may navigate in the alibi memory with or
keys after entering the date.
3. The weighing data in the alibi memory is indicated on the display.
4. Press key to print this record and the previous nine weighing.
5. Press key 4 times to return operation.
Search with weight value:
1. Press key after selecting NET, gross or tare which is suitable in parameter 813.
2. Press numerical keys to enter weight value in the printout data and press key.
3. The alibi record is indicated on the display.
4. Press key to print this record and the previous nine weighing.
5. Press key 4 times to return operation.
Transfer all Alibi records:
1. Go to the parameter [ 8-- METROLOGY ] main block in set up.
2. Press key 5 times to access parameter 814.
3. Press or keys to select PRNT and press key to start transferring.
4. Or you may stop transferring by pressing key.
About Alibi Memory:
1. Go to the parameter [ 8-- METROLOGY ] main block in set up.
2. Press key 6 times to access parameter 815.
3. Press key to print alibi information.