FT-112(D) Panel Weighing Indicator, Technical Manual, Rev.1.0.0, May 2019 Page 77 of 170
Data Entry to the linked memories together with ID memory
You may enter data into the related memories together with data entry to the items from ID memories for easy
use as;
For example, if ID1 is interrelated with SET and PT memories by parameter 373, the data entry can be done to
the item 111 as described below.
1. Press key for more than 2 seconds in weighing operation. The [ MEMORY ] prompt will be
displayed.
2. Press key to enter ID1 memory. [ID1: 001 ] message appears. The number on the right is
the memory code.
3. Enter the code numerically (for example 111) or use or keys to navigate in the ID memory.
4. The Identification data in the memory appears on the display after pressing key. Enter the new
alphanumeric ID data up to 32 digits and press key.
5. The limit values of the item appears [ SET 111-SP1 ] [ 0.0 kg ] on the display. Enter the limit
values in sequence.
6. The specific tare of item appears on the display [ PT 111: ] [ 0.0 kg ]. Enter the new PT value
and press key.
7. The following memory code appears [ ID1 112 : ].
8. Press key to go on entry or press key to exit.
Select data from linked memories
1. Press the identification key . The ID1 data appears
2. Press key to go into the memory.
3. After the last used code appeared [ ID1 :123 ], enter the ID memory code of the item.
4. Press key to select the identification data and link data to ID1, which are displayed in sequence.
The instrument returns to the operation mode after loading the selected item.
5. Or press key to return without any select.