4. Connect the USB connector of the USB battery charger to the USB-C connector in
the connector bay of the camera.
5. To check the status of the battery charging, do one of the following:
If the camera is turned on: Place your finger at the top of the screen and swipe
down. The battery status is displayed on the swipe-down menu.
If the camera is turned off: The battery charging indicator is displayed on the
screen.
6. It is good practice to disconnect the USB battery charger from the mains socket when
the battery is fully charged.
#T810587; r. AD/90967/90989; en-US
23

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the FLIR E54 and is the answer not in the manual?

FLIR E54 Specifications

General IconGeneral
Resolution320 x 240 pixels
Accuracy±2°C (±3.6°F) or ±2% of reading
Field of View24° × 18°
FocusManual
Digital Camera5 MP
Laser Distance MeterNo
Image ModesMSX, Picture-in-Picture
ConnectivityWi-Fi, Bluetooth
Battery Life4 hours
Storage MediaSD card
Weight1 kg
Minimum Focus Distance0.15 m
Spectral Range7.5 – 14 µm
Operating Temperature Range-15°C to 50°C
Storage Temperature Range-40°C to 70°C
Thermal Sensitivity< 0.04°C (40 mK)