Cleaning the camera
26
26.1 Camera housing, cables, and other items
26.1.1 Liquids
Use one of these liquids:
Warm water
A weak detergent solution
26.1.2 Equipment
A soft cloth
26.1.3 Procedure
Follow this procedure:
1. Soak the cloth in the liquid.
2. Twist the cloth to remove excess liquid.
3. Clean the part with the cloth.
CAUTION
Do not apply solvents or similar liquids to the camera, the cables, or other items. This can cause
damage.
26.2 Infrared lens
26.2.1 Liquids
Use one of these liquids:
A commercial lens cleaning liquid with more than 30% isopropyl alcohol.
96% ethyl alcohol (C
2
H
5
OH).
26.2.2 Equipment
Cotton wool
26.2.3 Procedure
Follow this procedure:
1. Soak the cotton wool in the liquid.
2. Twist the cotton wool to remove excess liquid.
3. Clean the lens one time only and discard the cotton wool.
WARNING
Make sure that you read all applicable MSDS (Material Safety Data Sheets) and warning labels on con-
tainers before you use a liquid: the liquids can be dangerous.
CAUTION
Be careful when you clean the infrared lens. The lens has a delicate anti-reflective coating.
Do not clean the infrared lens too vigorously. This can damage the anti-reflective coating.
#T559845; r. AJ/37554/37554; en-US
132

Table of Contents

Other manuals for FLIR E60

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the FLIR E60 and is the answer not in the manual?

FLIR E60 Specifications

General IconGeneral
Resolution320 x 240 pixels
Thermal Sensitivity<0.05°C at 30°C
Field of View25° x 19°
Battery Life4 hours
Spatial Resolution1.36 mrad
Image Frequency60 Hz
MeterLinkYes
Laser PointerYes
Text AnnotationYes
Storage MediaSD card
Spectral Range7.5 – 13 µm
Temperature Range-20°C to +650°C
Display3.5" LCD touchscreen
FocusManual
Accuracy±2°C or ±2% of reading
Image ModesThermal, visual, MSX
Voice AnnotationYes
Battery TypeLi-Ion battery
Minimum Focus Distance0.4 m
Operating Temperature Range-15°C to +50°C
Storage Temperature Range-40°C to +70°C
ConnectivityWi-Fi, USB
Image StorageJPEG