Air requirements
The HyPlex Prime pump requires a source of air be
-
tween 90 and 120 psi (6.2 and 8.3 bar). The air must be
dry and filtered to 10 microns.
On the Basic and Standard versions of the pump, the
manual air regulator should be adjusted and set at the
point at which 55,000 psi water pressure is achieved
with the correct orifice installed and the nozzle open.
Environment requirements
Ambient temperature around the pump must be main
-
tained between 45°F and 104°F (7°C and 40°C) to
ensure proper functioning of the pump.
High-pressure tubing
High-pressure tubing certified for continuous operation
at 60,000 psi (4140 bar) is used to route high-pressure
water from the HyPlex Prime pump to the cutting equip
-
ment.
Note: Refer to manual M-127, Small High-pressure Com
-
ponents for more information on high-pressure tubing,
components, and related service.