Mandatory maintenance schedules
At fixed intervals for the life of the pump, you must per
-
form a mandatory maintenance kit installation.
For all HyPlex Prime pumps (except the standalone ver
-
sion), the Service information feature in FlowCUT is fac
-
tory-set to remind the operator 10 hours before the next
required maintenance hour mark (these are listed below).
Maintenance periods by pump hours
Every 500 hours for a 30 hp pump and every 300 hours
for a 50 hp pump you must install a maintenance kit.
•
Complete kit bills of material are in Chapter 5
•
Complete kit installation procedures are in Chapter 4
26 | M-416 ©FlowInternationalCorporation
HYPLEX PRIME PUMP
Maintenance & Service Manual