Use cleaning solvents only in well-ventilated areas.
Avoid prolonged breathing fumes and contact with
skin or eyes.
Inspect the entire system before operating it.
Correct any fault or malfunction.
Tools
Use only approved test equipment, and check it reg
-
ularly for correct operation and calibration.
Use the correct tools—the incorrect tool can result in
injury to personnel or costly damage to the equip
-
ment.
Clear all tools and rags from around the machine af
-
ter service and before starting the equipment.
Use only approved work platforms. Never climb on
or around the equipment using makeshift devices.
Protective clothing
Do not wear loose clothing or jewelry while working
around rotating parts of machinery.
Pressurized air can drive particles into eyes and skin
if handled improperly. To prevent injury, use appro-
priate protective equipment and clothing and exer-
cise extreme caution.
Torque specifications
Refer to the following table when specific torque re
-
quirements are not listed in a service procedure.
CAUTION
Never torque mounting bolts and machine screws
beyond the manufacturer’s recommended limits.
The torque values for high-pressure water assemblies
and fittings are listed in U.S. Customary System foot-
pounds (ft-lb) and Systéme International (SI) Newton-
meters (N-m).
High-pressure
gland nuts
U.S.
ft-lb
SI
N-m
1
4
in. 15–25 20–34
3
8
in. 35–45 47–60
9
16
in. 60–75 80–100
24 | M-416 ©FlowInternationalCorporation