EasyManua.ls Logo

Fluke 105B - Page 50

Fluke 105B
185 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3 - 6 92B/96B/99B/105B Users Manual
Page 4 of 7:
A DC METER Measure the DC current in Meter mode
with a Current probe (available as an option) that is
connected to the INPUT A BNC. This is done with DC-
coupled input. A list box enables you to select the proper
range: 1, 10, 100 mV/A, or 1 V/A.
A AC METER Measure the AC current in Meter mode
with a Current probe (available as an option) that is
connected to the INPUT A BNC. This is done with DC-
coupled input. A list box enables you to select the proper
range: 1, 10, 100 mV/A, or 1 V/A.
A AC+DC METER Measure the AC+DC current in
Meter mode with a Current probe (available as an option)
that is connected to the INPUT A BNC. This is done with
DC-coupled input. A list box enables you to select the
proper range: 1, 10, 100 mV/A, or 1 V/A.
A DC EXTmV Measure the DC current in EXT.mV
mode with a Current probe (available as an option) that is
connected to the red and black 4-mm banana jacks. This is
done with DC-coupled input. A list box enables you to
select the proper range: 1, 10, 100 mV/A, or 1 V/A.
A AC EXTmV Measure the AC current in EXT.mV
mode with a Current probe (available as an option) that is
connected to the red and black 4-mm banana jacks. This is
done with DC-coupled input. A list box enables you to
select the proper range: 1, 10, 100 mV/A, or 1 V/A.
A AC+DC EXTmV Measure the AC+DC current in
EXT.mV mode with a Current probe (available as an option)
that is connected to the red and black 4-mm banana jacks.
This is done with DC-coupled input. A list box enables you
to select the proper range: 1, 10, 100 mV/A, or 1 V/A.

Table of Contents