Using Additional Capabilities 6 - 17
USING THE WAVEFORM GENERATOR
Press and then to open the GENERATE menu.
You can now select a waveform output at the red (GENE-
RATOR OUT) and black (COMmon) 4-mm banana jacks.
Figure 6-9. Generator Menu
1. Select GENERATOR OUTPUT and turn the generator
on and off.
2. Choose one of the six waveforms:
Square wave: 1.95kHz, 976Hz, or 488Hz (all at
5V p-p)
Sine wave: 976 Hz (1V p-p)
Slow ramp: Voltage (-2V to +2V, 1 mA maximum)
Current (0 to 3 mA, 2V maximum)
The generator is automatically disabled in the , ,
and mode.
The generator output can also be selected as trigger
source; when turned on, it replaces the EXT (external)
trigger source in the TRIGGER menu.
TESTING COMPONENTS
Figure 6-10. Component Test Setup
From the Special Functions menu, press to use the
ScopeMeter test tool as a predefined measuring tool for
components. This opens the Component Test menu.
1. Select COMPONENT MENU and turn the component
test on and off.
92B