Device Info
Information about your Meter is in the Device Info menu.
This information includes the:
•
Serial
numbe
r
•
Software
version
• Emissivity value (See Emissivity Selection
for more
informatio
n on
the emissivity value.)
•
Internal sensor se
nsitivity
•
Database Free Spac
e
Battery Selection
To change the battery type:
1.
Go to the Device Settings menu.
2. Push and to highlight Batter
y Selection
.
3. Push
to o
pen the menu.
4. Push and to highligh
t
the battery type you
have in the Meter.
5. Push t
o update the Meter an
d exit the
menu.
Emissivity Selection
The correct emissivity value is important for you to make
the most accurate temperature measurements. Most
painted or oxidized surfaces have an emissivity of 0.93
(default value set in the Meter). This is correct for non-
contact temperature measurements on most bearing
housings.
Inaccurate measurements can result from shiny or
polished metal surfaces. To compensate, put masking
tape or flat black paint on the measurement surface. Make
sure that the tape is the same temperature as the
measurement surface before you make a measurement.
For other applications the Meter has additional preset
emissivity values:
•
Aluminum
(e=0.30)
•
Iron
(e=0.7
0)
• Steel
(e=0.80)
• Paint (e=0.93) – default value
•
Woo
d (e=0.94)
•
Conc
rete
(e=0.95)