805/805 FC
Users Manual
14
External Sensor
In addition to the integrated vibration sensor, an optional
external sensor connects to the Meter. The connector type
for the external sensor is a Subminiature version B (SMB).
Figure 3 shows how to connect an external sensor to the
Meter.
Note
Fluke supports, but does not provide, external
sensors.
gqi05.eps
Figure 3. External Sensor Connection (805 shown)
Note
High frequency measurement (Crest Factor+) and
Temperature measurement automatically turn off
when an external sensor is connected to the
Meter.
To connect:
1.
Open the connector cover and push the
external
s
ensor into position.
2. Push to open the E
nter Sens
itivity menu.
Note
You must set the sensitivity in mV/g units.
3.
Use the navigation keys to select a characte
r in
the menu.
4. Push
to input the c
harac
ter into the field.
5.
Repeat steps 2 and 3 for additional characters.
6. Push
t
o store th
e value in the Meter and exit
the menu.
7. Push to start data
collectio
n.
The Mete
r automatically detects when you disconnect the
external sensor and is set to measure with the internal
sensor.