8.8 ASL Pressure
The set ASL (Above Sea Level) function is used to calibrate an altitude sensor. When an altitude sensor is
connected, change the [Air pressure] setting until the altitude is at 0m.
Setup:
1. Make sure that your TX and RX are bound and turned on.
2. Set your model on the ground.
3. Use the “UP”and “DOWN” keys to change the hPa value. If the system is showing a positive
altitude, reduce the hPa value until the altitude reaches 0m. If the system is showing a negative altitude
increase the hPa value until it reaches 0m.
4. To return to default settings press and hold the "OK" key for 3 seconds,press and hold the "CANCLE"
key to save.
Note: Make sure that your model is at ground level during this process.
8.9 i-BUS Setup
This function is used to set up the i-BUS module. The i-BUS module can be used to add servos to your
model that may be too far away from the receiver.
Setup:
1. Use the "UP" and "DOWN" keys to choose a channel and press "OK".
2. Press the button on the i-bus module that corresponds to the desired output, the system will then
return to the previous menu.
3. After setting up the desired channels press and hold the "CANCEL" key to save and exit.
8.10 Servos Freq
This function sets the frequency that the receiver outputs to the servos. Check your servos usermanual to
find the correct setting.