Program Program
Code Function Code Description Entry Code
Issue/Rev. 0.3 (8/97) 23
105 Product 4 Alarm Check/Reset Read only, Press E to clear None 105
Available Alarms
BH: Blend High LF: Low Flow
BL: Blend Low LP: Low Pressure
BP: Back Pressure LT: Low Temperature
CF: Not Configured Flow OA: Overrun
DA: Program Code PR: Pressure Transducer
DR: Density Transducer PS: Pulse Security
HD: High Density PT: Pulse Transmission Alarm
HF: Excess High Flow TP: Temperature Probe
HP: High Pressure UF: Unauthorized Flow
HT: High Temperature VF: Valve Fault
LD: Low Density ZF: Zero Flow
106 Recipe Alarms Check/Reset Read only, Press E to clear None 106
Available Alarms
DA: Program Code
107 Transaction Alarms To be read only None 107
108 Ready Mode Alarms To be read only None 108
109 Set Time Enter: Five digits. Two digits 109
for hours, Two digits for minutes
and one to indicate military,
time, AM or PM. The last digit will
be "0" = AM, "1" = PM and
"2" = Military (e.g., 01:130) __ __ __ __ __
110 Set Date Enter: Six digits. Two digits for 110
month followed by two digits for
day, followed by digits for
year (e.g., 011288) __ __ __ __ __ __
111 Dynamic Display Enter: Two digits in seconds 111
Time-out of time-out (e.g., 15)
"00" Display will remain till
the "CLEAR" key is pressed
"99" will disable the dynamic displays. __ __