Program Program
Code Function Code Description Entry Code
40 Issue/Rev. 03 (8/97)
754 EIA-485 Printer Enter: "0" No 485 Security 754
Security "1" XON/XOFF
"2" DEC Protocol
"3" PTB - FX Protocol
"4" PTB - LQ Protocol __
Note: Options 3 and 4 of this code apply to RBU-02 and above firmware.
755 Shared Printer Enter: "0" No Security Alarm 755
Security Alarm "1" Local Security Alarm
"2" Prg Security Alarm __
Note: Used with DEC Security.
756 Select Volumes to Enter: Five digit number indicating 756
Print the totals that will be printed
on the Product Receipt Ticket.
1st digit - Raw Totals
2nd digit - Gross Totals
3rd digit - Gross at Standard
Temperature Totals
4th digit - Net Totals
5th digit - Mass Totals
A zero in the digit indicates
the total will not be printed,
a one indicates the total
will be printed. (e.g., 01100
indicates that Gross totals
and the Gross at Standard
Temperature will be printed
on the Product Receipt Ticket.) __ __ __ __ __
Note: The current load ticket can have all five of the volumes printed on it. However, any reprint of that load ticket will only contain the totals that
have been selected for local storage in code 307 and in this program code.