Program Program
Code Function Code Description Entry Code
48 Issue/Rev. 03 (8/97)
858 Additive Injector Enter: Ten digits for converting the 858
Conversion Factor additive injector units (oz, cc etc.,) to
volume units (gal, liter, etc.,) when using
downstream additive injection. The first seven
digits are the base number, the eighth unit is
the exponent sign and the last two digits
are the exponent. The exponent sign is
entered as a zero for positive and a
one for negative. (e.g., 7.812500E-03
conversion for ounce to gallon.)
Note: If set to zero the AccuLoad II will not add the Additive volumes to the delivered product volumes.
__ . __ __ __ __ __ __ E __ __ __
859 Additive Injector Enter: Two digits defining 859
Feedback Errors the number of errors before alarming __ __
860 Injector #1 Feedback Enter: Three digits in seconds 860
Delay allowed between feedbacks before
an alarm. __ __ __
861 Injector #2 Feedback Enter: Three digits in seconds 861
Delay allowed between feedbacks before
an alarm. __ __ __
862 Injector #3 Feedback Enter: Three digits in seconds 862
Delay allowed between feedbacks before
an alarm. __ __ __
863 Injector #4 Feedback Enter: Three digits in seconds 863
Delay allowed between feedbacks before
an alarm. __ __ __
864 Injector #5 Feedback Enter: Three digits in seconds 864
Delay allowed between feedbacks before
an alarm. __ __ __