Batteries
10
Amp-Hour Consumption Formulas
(AC Amps x 10) x 1.1** x Hours of Operation = DC Amp-Hours
(AC Watts/DC Voltage*) x 1.1** x Hours of Operation = DC Amp-Hours
(AC Volt-Amps/DC Voltage*) x 1.1** x Hours of Operation = DC Amp-Hours
*DC Voltage is 12, 24 or 32 volts, depending on your system.
**1.1 is the inverter-efficiency correction factor.
Typical Power Consumption
The chart identifies typical power consumption for common
AC loads. Use it as a guide when identifying your power
requirements.
Many electric motors have momentary starting requirements
well above their operational rating. Start-up watts are listed
where appropriate. Individual styles and brands of appliances
may vary.
Note: The output power is a modified sine wave. Certain laser
printers, bread-makers, dimmer lights, variable speed tools,
digital clocks and appliance/tool chargers may not operate on
the inverter’s output power.