Operation
54
Troubleshooting LED Status
LED Status
INVERT CHARGE
LOW
BATTERY
OVERTEMP
OVERLOAD
Operation Status Notes
Solid
Green
Blinking
Green
Off Off Inverting. Charger is ready but
no external AC available.
Normal
Blinking
Green
Solid
Green
Off Off Inverter is in standby. Battery
is being charged.
Normal, changing current
limited if AC load exceeds
Power Sharing setting.
Blinking
Green
Off Off Off Inverter is in standby. Charger
manually turned off.
If AC power is removed and
reapplied, the charger will
automatically turn on.
Off
Solid
Green
Off Off
Inverter is off. Battery is being
charged.
Reset the inverter by pressing
the INVERT button. The
INVERT LED should blink.
Solid
Green
Blinking
Green
Solid Red * Inverting. Charger is ready but
no external AC available.
Battery voltage warning:
10V<volts DC>15V
Inverter shut down. Operation
will resume when battery
reached 13.5 volts.
Solid
Green
Blinking
Green
* Solid Red Inverting. Charger is ready but
no external AC available.
Charger over-temperature
warning
Warning. Inverter shut down
Off
Blinking
Green
Slow
Blinking
Red
*
Battery voltage shut down
10V<VDC>15V
Inverter shut down. Operation
will resume when battery
reached 13.5 volts.