Operation
66
To cancel equalizing
• Interrupt the AC power to the charger at any time during
the cycle.
Temperature Sensitive Charging (TSC)
When the battery temperature sensor is connected to the unit
and to the batteries, the charge voltage is controlled based on
battery temperature. The charger adjusts the charge voltage to
the best level. This minimizes water loss in wet cell batteries.
Charge voltage regulation optimizes the battery life cycle.
If the sensor is not connected, the charge voltage levels are set
to defaults based on the type of battery. See the “Battery
Charger Acceptance Voltage Settings in DC Volts” chart on
page 62 and the “Battery Charger Float Voltage Settings in DC
Volts” chart, on page 63.
To connect the TSC sensor
For instructions on installing the TSC sensor, see Installation
section, “Step 7: Install the optional Temperature Sensitive
Charging (TSC) sensor” on page 29.
REPLACING BATTERY CABLE FUSES
Battery cable fuses provide continued protection against the
possibility of fire. When the fuse blows, replace the battery
cable fuse with a fuse of the specified voltage, current and
type ratings. See Installation section, “Step 5: Install battery
cable fuses” on page 26 for specifications.