To equalize the batteries
Equalizing is recommended only for wet cell batteries. Do not
equalize gel cell or AGM batteries.
1. Do not equalize the batteries until they have completed
the full 3-stage charge cycle.
2. Remove all loads from the DC system. Some DC loads
may not tolerate the high charge voltage.
3. Provide proper ventilation for the battery fumes.
4. Check the battery electrolyte level. Ensure the plates are
covered. It is best not to completely top off the batteries
before you equalize.
5. Replace the battery caps. Leave the caps on while equaliz-
ing.
6. For instructions on starting the equalizing cycle, refer to
the Remote Control Panel or LINK instrument manual.
7. Monitor the equalizing charge cycle:
Do not allow any sparks.
If one or more cells begin to overflow, terminate the
equalizing charge cycle.
During the cycle:
The battery, state-of-charge LEDs will sequence on the
Remote Control Panel.
The red charge LED flashes on the LINK instrument.
8. If you do not interrupt the AC power to the charger, a
timer will stop the equalization charge cycle in 8 hours.
The charger automatically goes to float and
Green float LED battery status light is illuminated on
the Remote Control Panel.
Green float LED is lit on the LINK instrument.
9. Check the battery electrolyte level. Top off with distilled
water if necessary. This is a good time to perform routine
battery maintenance.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Freedom 458 Series COMBI and is the answer not in the manual?

Freedom 458 Series COMBI Specifications

General IconGeneral
BrandFreedom
Model458 Series COMBI
CategoryBattery Charger
LanguageEnglish

Related product manuals