Operation
62
Battery Charger Acceptance Voltage Settings in DC Volts
erutarepmeT0epyT1epyT2epyT3epyT
Fº Cº lleCteW*1leG*2leGMGA
021945.210.310.319.21
011346.315.310.419.31
001838.317.311.410.41
09230.418.312.411.41
08722.410.413.412.41
**07**124.411.414.413.41
06615.413.415.414.41
05015.414.415.415.41
045 5.515.415.415.41
031-5.515.415.415.41
*There are two settings for gel batteries. The Gel 1 setting is for
long battery life; the Gel 2 setting is for rapid charging. Check
with the battery manufacturer to determine the proper setting
for your batteries.
**Default setting when the temperature sensor is not con-
nected.
Stage 3Float Charge
When the acceptance stage is completed, the charge current
will shut off. The Freedom Inverter/Charger monitors the
battery voltage while it drifts down from the acceptance
charge voltage limit. When it reaches the float voltage set
point, the float charge stage engages.
The float charge stage holds the battery voltage constant, at a
preset lower level for long term battery maintenance. During
the float charge stage, the full output current of the battery
charger is available to operate any DC appliances that may be
on the system.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Freedom 458 Series COMBI and is the answer not in the manual?

Freedom 458 Series COMBI Specifications

General IconGeneral
BrandFreedom
Model458 Series COMBI
CategoryBattery Charger
LanguageEnglish

Related product manuals