WALL MOUNT GAS-FIRED WATER BOILER — Boiler Manual
16 Install water piping (continued)
This boiler is NOTINTENDEDFORCONNECTIONWITHA
REFRIGERATIONSYSTEM
Use two wrenches when tightening water piping
ATBOILERUSING ONE OFTHEWRENCHESTOPREVENT
THEBOILERINTERIORPIPINGFROMTURNING&AILURETO
support the boiler piping connections to prevent
THEMFROMTURNINGCOULDCAUSEDAMAGETOBOILER
components.
General piping information
!DDITIONALCONTROLSIFREQUIRED
The FreeStyle® control uses temperature sensors to
provide both high limit protection and modulating
temperature control. 4HE CONTROLS HIGH LIMIT
FUNCTION REQUIRES MANUAL RESET
. Some codes/
jurisdictions may require additional external
CONTROLSFORHIGH LIMIT ANDOR LOWWATER CUTOFF
protection.
!DDITIONALLIMITCONTROLS
&OLLOWINGSTANDARDINDUSTRYPRACTICESIFINSTALLATIONISTOCOMPLY
WITH!3-%REQUIREMENTSANADDITIONALHIGHTEMPERATURELIMIT
MAYBE NEEDED#ONSULTLOCAL REQUIREMENTSFOR OTHER CODES
STANDARDSTODETERMINEIFNEEDED
1. Install a manual reset high temperature limit to prevent a
temperature above 200°F in system supply piping between
boiler and isolation valve. (Note that the control operating
LIMITFUNCTIONSHUTSTHEBOILERDOWNAT&ORLOWERIFSET
to a lower value.)
-ULTITEMPERATURESYSTEMS)FTHEHEATINGSYS-
tem includes circuits that require lower temperature
WATERRADIANTSLABCIRCUITSFOREXAMPLEASWELLAS
higher temperature circuits, it is recommended to
protect low temperature circuits with limit controls
that are wired to the control external limit circuit
terminals.
,OWTEMPERATURESYSTEMS)FUSINGTEMper-
ature-limited materials (such as PEX tubing) in
system piping, it is recommended to protect the
system with limit controls that are wired to the
controls external limit circuit.
2. See instructions beginning on page 50FORWIRINGINFORMATION
3. )FUSINGAMANUALRESETLIMITCONTROLORWIRINGINTHEMANUAL
reset circuit, set FreeStyle® control boiler limit at least 20°F
less than the external manual reset limit (i.e., set FreeStyle®
CONTROLNOHIGHERTHAN&FORA&EXTERNALLIMITFOR
example).
"ACKmOWPREVENTER
1. 5SEBACKmOWPREVENTERINTHECOLDWATERSUPPLYPIPINGIF
required by local codes.
System/zone pipe sizing
"ASEBOARDCONVECTORSORCASTIRONRADIATORS/.,9
1. For residential space heating applications (other than radiant
heating or unit heaters) ONLY, you can use the sizing sug-
gestions in Figure 43.
Studies have indicated that dangerous bacteria
CANFORMINPOTABLEWATERDISTRIBUTIONSYSTEMS
IFCERTAINMINIMUMWATERTEMPERATURESARENOT
MAINTAINED#ONTACTLOCALHEALTHDEPARTMENTFOR
MOREINFORMATION
Figure 43 3UGGESTEDPIPESIZINGFORSYSTEMHEADERS
ANDZONEPIPING2%3)$%.4)!,WITH
BASEBOARDCONVECTORSORCASTIRONRADIATORS
/.,9&TEMPERATURERISE
System water piping methods
0RIMARYSECONDARYPIPINGTOBOILER
5SINGPRIMARYSECONDARYPIPINGWILLPROVIDETHEMOSTEFlCIENT
ANDRELIABLEOPERATIONOFTHEBOILERANDTHEHEATINGSYSTEM
1. 5SEINFORMATIONBEGINNING ON page 37 TOSIZE PUMP FOR
proper flow through the
FreeStyle® boiler.
2EFERENCESUGGESTEDPIPINGLAYOUTSONPAGES38-43.
FreeStyle
®
-ODEL 3YSTEMHEADER
&3 vORLARGER
2ECOMMENDATIONSAREBASEDONA&TEMPERATUREDROP
THROUGHTHESYSTEM
3UGGESTEDMAXIMUMLOADPERZONE
#OPPERPIPEAND
BASEBOARDSIZE
-AXIMUMRECOMMENDED
FEETOFBASEBOARD
Ðv 67
v
3IZEZONECIRCULATORSTOHANDLETHEREQUIREDmOWANDHEAD
LOSSFOREACHZONE