Part number 550-142-850/0716
12
FreeStyle
®
WALL MOUNT GAS-FIRED WATER BOILERBoiler Manual
4 Converting boiler to propane
Prepare boiler for propane (if required)
FreeStyle
®
80/120/155
Propane operation
!,,FreeStyle
®
BOILERSMUSTBECON-
VERTEDFORPROPANEOPERATION.
#ONVERTINGANEXISTINGNATURALGASlRED
BOILERFORPROPANE
For a boiler already
INSTALLEDYOUMUSTTURNOFFGASSUPPLYTURNOFF
POWERANDALLOWBOILERTOCOOLBEFOREPROCEED-
ING9OUMUSTALSOCOMPLETELYTESTTHEBOILERAFTER
CONVERSIONTOVERIFYPERFORMANCEANDSTARTUP
THEBOILERFOLLOWINGINSTRUCTIONSBEGINNINGON
page 70OFTHISMANUAL
6ERIFY#ONVERSIONKIT—See Figure 8.
LP gas venturi will have a black label and will be
clearly labeled “LPG”.
Natural gas venturi will have a white label and
will be clearly labeled NG”.
Failure to comply could result in severe personal
injury, death or substantial property damage.
Figure 8 .ATURALAND,IQUElED0ETROLEUM0ROPANEGAS
CONVERSIONKITS
Boiler Model +IT0ART.UMBER
&3.'
640-000-022WT
&3,0
640-000-024WT
&3.'
640-000-023WT
&3,0
640-000-025WT
&3.'
640-000-082WT
&3,0
640-000-083WT
This conversion kit shall be installed by a qualified
service agency in accordance with the
manufacturer’s instructions and all applicable codes
and requirements of the authority having jurisdiction.
If the information in these instructions is not followed
exactly, a fire, an explosion or production of carbon
monoxide may result causing property damage,
personal injury or loss of life. The qualified service
agency is responsible for the proper installation of this
kit. The installation is not proper and complete until
the operation of the converted appliance is checked as
specified in the manufacturer’s instructions supplied
with the kit.
s Follow all instructions in proper order.
s $O NOT TAMPER WITHVENTURI $/ ./4CHANGE OR MODIFY
venturi in any way.
s Do not leave an uninstalled venturi in the building.
s #AUTIONTHEGASSUPPLYSHALLBESHUTOFFPRIORTODISCONNECTING
THEELECTRICALPOWERBEFOREPROCEEDINGWITHTHECONVERSION
Label all wires prior to disconnection when servic-
ing controls. Wiring errors can cause improper and
dangerous operation.
&3.'P/N 640-000-022WT LP to Natural Gas Conversion Kit contents:
36602390 Venturi - Natural Gas 10.6 m
1
35105080 Gasket Nitrile Rubber 167 x 63.5X3.53 NBR
1
3541F210 Label Gas Conversion
1
3541G190 Label FS-80 Rating Plate Conversion NG 1
550-142-855 Instructions Conversion LP to Natural Gas 1
&3.'P/N 640-000-023WT LP to Natural Gas Conversion Kit contents:
36602400 Venturi - Natural Gas 12.6 m
1
35105080 Gasket Nitrile Rubber 167 x 63.5X3.53 NBR
1
3541F210 Label Gas Conversion
1
3541G480 Label FS-120 Rating Plate Conversion  1
550-142-855 Instructions Conversion LP to Natural Gas 1
&3,0P/N 640-000-024WT NG to Propane Gas Conversion Kit contents:
36602430 Venturi - 10.6 GPL
1
35105080 Gasket Nitrile Rubber 167 x 63.5X3.53 NBR
1
3541F210 Label Gas Conversion
1
3541G190 Label FS-80 Rating Plate Conversion LP 1
550-142-854 Instructions Conversion Nat to LP Gas 1
&3,0P/N 640-000-025WT NG to Propane Gas Conversion Kit contents:
36602450 Venturi - 12.6 GPL
1
35105080 Gasket Nitrile Rubber 167 x 63.5X3.53 NBR
1
3541F210 Label Gas Conversion
1
3541G200 Label FS-120 Rating Plate Conversion LP 1
550-142-854 Instructions Conversion Nat to LP Gas 1
&3,0P/N 640-000-08WT NG to Propane Gas Conversion Kit contents:
36602880 Venturi - 16.6 GPL
1
35105080 Gasket Nitrile Rubber 167 x 63.5X3.53 NBR
1
3541F210 Label Gas Conversion
1
3541G200 Label FS-1 Rating Plate Conversion LP 1
550-142-854 Instructions Conversion Nat to LP Gas 1
&3.'P/N 640-000-082WT LP to Natural Gas Conversion Kit contents:
36602870 Venturi - Natural Gas 16.6m
1
35105080 Gasket Nitrile Rubber 167 x 63.5X3.53 NBR
1
3541F210 Label Gas Conversion
1
3541G480 Label FS-1 Rating Plate Conversion  1
550-142-855 Instructions Conversion LP to Natural Gas 1
.ATURALTO,0#ONVERSION+IT0ART.UMBERS
,0TO.ATURAL#ONVERSION+IT0ART.UMBERS