EasyManua.ls Logo

Freestyle 80 - Page 93

Freestyle 80
128 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Part number 550-142-850/0716
93
FreeStyle
®
WALL MOUNT GAS-FIRED WATER BOILERBoiler Manual
32 Troubleshooting(continued)
Parameter Description Default Note
P33




--
30
--
30
DHW conf. dependent
P34




--
15
--
15
DHW conf. dependent
Figure 118hT3v4RANSPARENT0ARAMETERMODEFORFreeStyle
®
BOILERSCONTINUED
"YPRESSINGTHE2%3%4PUSHBUTTONFORSECONDITISPOSSIBLETOESCAPEFROMTHEh4RANSPARENTPARAMETERvMODE"YPRESSINGTHE
2%3%4PUSHBUTTONFORSECONDSITISPOSSIBLETOLEAVETHE)NSTALLERMODE)FNOACTIONHASBEENTAKENTHE--)AUTOMATICALLY
LEAVESTHISMODEAFTERMINUTES
t01 blinking
CH Supply sensor1 Temperature (°F) between 32 and 257
t02 blinking
CH Supply sensor2 Temperature (°F) between 32 and 257
t03 blinking
CH Return sensor Temperature (°F) between 32 and 257
t04 blinking
DHW sensor Temperature (°F) between 32 and 257
t05 blinking
Outdoor sensor Temperature (°F) between -22 and 158, blinking if it is negative
t06 blinking
Exhaust sensor Temperature (°F) between 32 and 257
F07 blinking
Actual Fan Speed (Hz) 
L08 blinking
Actual burner load (%) 
F09 blinking
 between 00 and 255
Figure 119$EFAULT#ONTROL"OARDh4RANSPARENT0ARAMETERSvFORFreeStyle
®
BOILERS
Boiler
Model
“b01” “b02” “b04” “b05” “b06” “b10” “b12” “P01” “P02” “P04”
Gas type
Boiler
type
Fan Max.
Freq. in DHW
Fan Max.
Freq. in CH
Fan Min.
Freq. in CH
S/W mode
selection button
Var. Out
Relay
Ignition
level
CH Slope
(F/min)
CH
Off Time
FS-80-N-C
 3 155 155 40 1 0 80 11 2
FS-120-N-C
 3 200 200 40 1 0 60 11 2
FS-155-N-C
 3 205 205 39 1 7 60 11 2
FS-80-N-H
 2 155 155 40 1 0 80 11 2
FS-120-N-H
 2 200 200 40 1 0 60 11 2
FS-155-N-H
 2 205 205 39 1 0 60 11 2
FS-80-LP-C
 3 145 145 40 1 0 80 11 2
FS-120-LP-C
 3 185 185 40 1 0 60 11 2
FS-155-LP-C
 3 200 200 40 1 7 60 11 2
FS-80-LP-H
 2 145 145 40 1 0 80 11 2
FS-120-LP-H
 2 185 185 40 1 0 60 11 2
FS-155-LP-H
 2 200 200 40 1 0 60 11 2
“In” as Inquiry mode
Selecting “In the display starts with showing TvBLINKING"YMEANSOFTHE#(AND#(PUSHBUTTONSITISPOSSIBLETOSELECTTHE
parameters; between “T and “F13v3ELECTINGONEOFTHESEPARAMETERSBYMEANSOFTHE$(7AND$(7PUSHBUTTONSISPOS-
SIBLETOSEEHISVALUENOTmASHINGONLYINCASEOFNEGATIVEOUTDOORTEMPERATURETHEVALUEISmASHING
Figure 120h)Nv)NQUIRYMODEFORFreeStyle
®
BOILERS

Table of Contents

Other manuals for Freestyle 80