EasyManuals Logo

Froling Turbomatic TMC 28-55 User Manual

Froling Turbomatic TMC 28-55
31 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #13 background imageLoading...
Page #13 background image
Technology
Technical Specifications
Fröling Heizkessel- und Behälterbau Ges.m.b.H, Industriestrasse 12, A-4710 Grieskirchen Page 13
Tel +43 (0) 7248 606-0 Fax +43 (0) 7248 606-600 info@froeling.com www.froeling.com
M1010108_en
2
Test data for operation with pellets
Description Unit 28 35 48 55
Testing institute BLT Wieselburg
Test report no. 014/00 009/00
Date of issue 22.05.2000
1)
1)
25.04.2000
Carbon monoxide (CO)
Rated load
Partial load
mg/MJ
31.00
56.00
31.52
65.07
32.48
81.93
33.00
91.00
Nitrogen oxide (NOx)
Rated load
Partial load
mg/MJ
59.00
not measured
64.96
not measured
76.04
not measured
82.00
not measured
Organic hydrocarbons
Rated load
Partial load
mg/MJ
<1
1.00
<1
1.00
<1
1.00
<1
<1
Dust
Rated load
Partial load
mg/MJ
6.00
not measured
7.81
not measured
11.19
not measured
13.00
not measured
Boiler efficiency rating
Rated load
Partial load
%
92.00
91.90
91.64
91.87
90.96
91.83
90.60
91.80
1) Values for boiler sizes 35 kW and 48 kW are interpolated (calculated as per EN 303-5)