25
EN
Temperature
monitoring
Temperature monitoring prevents the battery from being charged or discharged if it is out-
side the permitted temperature range.
If the battery falls below the permitted temperature range:
- "cold" appears on the temperature indicator
- neither welding nor charging is possible
- After approx. 5 seconds the temperature indicator goes out and operations in pure
welding mode is possible again.
The charging operation can be carried out at a battery temperature of -10°C and
above
If the battery exceeds the permitted temperature range:
- "hot" appears on the temperature indicator
- no welding or charging operation possible until the temperature indicator goes out
Overcharge pro-
tection
Once the battery has been fully charged, the charger turns off automatically and switches
to conservation charging mode.
In this mode the device can remain connected to the charger for any period of time.