EasyManua.ls Logo

Fronius AccuPocket 150/400 - Setup Menu and Parameters

Fronius AccuPocket 150/400
50 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
43
EN
1)
D.C. = Duty cycle
Operating envi-
ronments
40 °C (104 °F) 50% D.C.
1)
100 A
40 °C (104 °F) 100% D.C.
1)
65 A
Open circuit voltage 91 V
Reduced open circuit voltage
(only with VRD option)
14 V
Protection class IP 23
Type of cooling AF
Mark of conformity CE, S
Dimensions (l x w x h) 435 x 160 x 310 mm
17.1 x 6.3 x 12.2 in.
Weight 10.9 kg (24.3 lb.)
Transport, storage or operation of the charger outside the stipulated area will
be deemed improper. The manufacturer shall not be held liable for any dam-
age arising from such usage.
Ambient temperature range:
- during operation: -10 °C to +40 °C (14 °F to 104 °F)
- during transport and storage: -20 °C to +55 °C (-4 °F to 131 °F)
- recommended temperature range during charging: + 4 °C to + 40 °C (+
39,2 °F to + 104 °F)
Relative humidity:
- up to 50 % at 40 °C (104 °F)
- up to 90 % at 20 °C (68 °F)
The surrounding air must be free from dust, acids, corrosive gases or sub-
stances, etc.
Can be used at altitudes up to 2000 m (6561 ft.)

Table of Contents