39
EN
Make a note of the error numbers shown in the display, and of the serial number and con-
figuration of the power source, and contact our after-sales service team with a detailed de-
scription of the error.
E02 / E03 / E05 / E06
Cause: Internal temperature sensor fault on ACCUPLT / ACCUPLT-TIG PC board
Remedy: Contact after-sales service
E07
Cause: 15 V supply voltage too low
Remedy: Contact after-sales service
E09 / E10
Cause: Impedance load too high on power source output
Remedy: Use power source correctly (welding)
E11
Cause: No communication with the control panel
Remedy: Contact after-sales service
E12 / E13 /E14
Cause: Internal error on ACCUPLT / ACCUPLT-TIG PC board
Remedy: Contact after-sales service
E16
Cause: Communication error between battery and ACCUPLT / ACCUPLT-TIG PC
board
Remedy: Contact after-sales service
E018
Cause: Wrong firmware (software) has been loaded
Remedy: Contact after-sales service
E19 / E22
Cause: Battery fault
Remedy: Contact after-sales service
E23
Cause: A voltage of > 113 V DC has been measured on the welding sockets
Remedy: Contact after-sales service
No function The device cannot be switched on
Cause: The battery has entered a state of deep discharge as it has been stored for
too long without being charged
Remedy: Charge the battery now
Battery operation is possible again above 25% capacity.
If charging is no longer possible, contact After-Sales Service.
Cause: Control panel defective
Remedy: Contact After-Sales Service

Table of Contents