EasyManua.ls Logo

Fronius AccuPocket 150/400 - Page 42

Fronius AccuPocket 150/400
50 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
40
Battery is not charged
Device is connected to the charger, charger is connected to the mains, no "Charging" in-
dicator on the power source
Cause: Device is too hot
Remedy: Check/reduce ambient temperature, allow battery to cool down
Cause: Device temperature too low
Remedy: Check/increase ambient temperature
No welding current
Device switched on, indicator for the selected welding process is lit
Cause: Break in the welding cable connection
Remedy: Check the plug connections
Cause: Poor or no earth
Remedy: Establish a connection to the workpiece
Cause: There is a break in the power cable in the welding torch or electrode holder
Remedy: Replace welding torch or electrode holder
No welding current
Device switched on, indicator for the selected welding process is lit, overtemperature indi-
cator lit
Cause: Duty cycle exceeded - device overloaded - fan running
Remedy: Keep within duty cycle
Cause: Thermostatic automatic circuit breaker has tripped
Remedy: Wait until the power source automatically comes back on after the end of the
cooling phase
Cause: The fan in the power source is faulty
Remedy: Contact after-sales service
Cause: Insufficient cooling air intake
Remedy: Ensure adequate air supply
Cause: Air filter is dirty
Remedy: Clean air filter
No welding current
Device switched on, indicator for the selected welding process is lit, overtemperature indi-
cator lit
Cause: Power module error
Remedy: Turn off the device, then turn it on again.
If the error occurs frequently, contact after-sales service

Table of Contents

Other manuals for Fronius AccuPocket 150/400

Related product manuals