dSP | Exx
Cause: Fault in the central control and regulation unit
Remedy: Contact After-Sales Service
dSP | Sy
Cause: Fault in the central control and regulation unit
Remedy: Contact After-Sales Service
dSP | nSy
Cause: Fault in the central control and regulation unit
Remedy: Contact After-Sales Service
E-S | toP
only with the External stop and External stop - inching enabled options
Cause: The External stop or External stop - inching enabled option has tripped
Remedy: Acknowledge the service code via the robot control unit and re-apply the 24
V SELV safety voltage
EFd | xx.x
Cause: Fault in the wire feed system (overcurrent in wire-feed unit drive)
Remedy: Arrange the hosepack in as straight a line as possible; check that there are
no kinks or dirt in the inner liner; check the contact pressure on the 2-roller (or
4-roller) drive
Cause: Wire-feed unit motor is sticking or defective
Remedy: Check or replace the wire-feed unit motor
EFd | 8.1
Cause: Fault in the wire feed system (overcurrent in wire-feed unit drive)
Remedy: Arrange the hosepack in as straight a line as possible; check that there are
no kinks or dirt in the inner liner; check the contact pressure on the 2-roller (or
4-roller) drive
Cause: Wire-feed unit motor is sticking or defective
Remedy: Check or replace the wire-feed unit motor
EFd | 8.2
Cause: Fault in the wire feed system (overcurrent in wire-feed unit drive)
Remedy: Arrange the hosepack in as straight a line as possible; check that there are
no kinks or dirt in the inner liner; check the contact pressure on the 2-roller (or
4-roller) drive
EFd | 9.1
Cause: The external supply voltage has dropped below the tolerance range
Remedy: Check the external supply voltage
Cause: Wire-feed unit motor is sticking or defective
Remedy: Check or replace the wire-feed unit motor
EFd | 9.2
Cause: The external supply voltage has exceeded the upper limit of the tolerance
range
Remedy: Check the external supply voltage

Table of Contents

Other manuals for Fronius CMT 4000 Advanced

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius CMT 4000 Advanced and is the answer not in the manual?

Fronius CMT 4000 Advanced Specifications

General IconGeneral
BrandFronius
ModelCMT 4000 Advanced
CategoryAC Power Distribution
LanguageEnglish

Related product manuals