80
Commissioning the TPS 2700
General Commissioning the TPS 2700 power source is described by reference to a manual gas-
cooled MIG/MAG application.
Recommenda-
tion for water-
cooled applica-
tions
- Use the PickUp trolley
- Fit the cooling unit to the PickUp trolley
- Fit the TPS 2700 power supply to the cooling unit
- Only use water-cooled welding torches with an external water connection
- Connect the water connections on the welding torch directly to the cooling unit
Connecting the
gas cylinder
Connecting the gas hose to the TPS 2700
Place the gas cylinder on a solid, level
surface in such a way that it remains
stable
Secure the gas cylinder to prevent it
from toppling over (but not around the
neck of the cylinder)
Take the protective cap off the gas cy-
linder
Briefly open the gas cylinder valve to
blow off any dust or dirt
Check the seal on the pressure regula-
tor
Screw the pressure regulator onto the
gas cylinder and tighten it
Connect the pressure regulator to the
shielding gas connection on the power
source using the gas hose
WARNING! If gas cylinders topple over, there is a risk of very serious injury and
damage. Place gas cylinders on a solid, level surface so that they remain stable.
Secure gas cylinders to prevent them from falling over.
Observe the safety rules of the gas cylinder manufacturer.
1
2
4
5
7
NOTE! US devices are supplied with an adapter for the gas hose:
- Glue in or seal the adapter
- Test the adapter to ensure that it is gas tight.