Fronius Primo
3.0-1 / 3.5-1 / 3.6-1 / 4.0-1
4.6-1 / 5.0-1 AUS / 5.0-1
5.0-1 SC / 6.0-1 / 8.2-1
Operating Instructions
Grid-connected inverter
Instructions de service
Onduleur pour installations photo-
voltaïques connectées au réseau
Gebruiksaanwijzing
Inverter voor netstroomgekoppelde
fotovoltaïsche installaties
ENFRNL
www.youtube.com/FroniusSolar
LEARN MORE WITH
OUR HOW-TO VIDEOS

Table of Contents

Other manuals for Fronius Primo 8.2-1

Questions and Answers

  • L
    Lauren MercadoSep 6, 2025
    What happens when AC frequency is too high on Fronius Primo 8.2-1 Inverter?
    • B
      barbara39Sep 6, 2025
      If the AC frequency is too high, the Fronius Inverter will resume feeding energy into the grid.
  • A
    Ashley TapiaAug 22, 2025
    What to do if error occurred during update process of Fronius Inverter?
    • L
      lauramoralesAug 22, 2025
      If an error occurred during the update process of your Fronius Inverter, re-download the update file. If the status code is still displayed, notify a Fronius-trained service engineer.
  • C
    Christopher LevineSep 3, 2025
    What happens when AC voltage is too high on Fronius Primo 8.2-1 Inverter?
    • W
      wbellSep 4, 2025
      If the AC voltage is too high, the Fronius Inverter will resume feeding energy into the grid.
  • J
    Jimmy MillerSep 2, 2025
    What happens when internal temperature is too high on Fronius Primo 8.2-1 Inverter?
    • M
      murrayjamesSep 2, 2025
      When the internal temperature of your Fronius Inverter is too high, the inverter resumes with its start-up routine.
  • J
    Jesse RuizSep 1, 2025
    How to resolve functional incompatibility on Fronius Primo 8.2-1 Inverter?
    • S
      sara15Sep 1, 2025
      To resolve functional incompatibility on your Fronius Inverter, update the inverter firmware. If the status code is still displayed, notify a Fronius-trained service engineer.
  • D
    Derek EvansAug 30, 2025
    What to do if Fronius Primo 8.2-1 shows no communication with power stage set?
    • F
      Frederick MckenzieAug 30, 2025
      If your Fronius Inverter displays a status code indicating no communication with the power stage set continuously, notify a Fronius-trained service engineer.
  • C
    carlafuentesAug 29, 2025
    How to fix invalid limit value settings on Fronius Primo 8.2-1?
    • C
      Cory BishopAug 29, 2025
      To address invalid limit value settings on your Fronius Inverter, update the inverter firmware. If the status code continues to appear, notify a Fronius-trained service engineer.
  • C
    Connor LucasAug 27, 2025
    What causes LOW PV VOLTAGE on Fronius Primo 8.2-1 Inverter?
    • C
      Catherine WaltersAug 27, 2025
      The 'LOW PV VOLTAGE' status code on your Fronius Inverter may appear due to the low level of insolation. If this status code occurs when there is sufficient insolation, contact your system engineer.
  • M
    Mr. Anthony FaulknerAug 26, 2025
    Why is my Fronius Inverter showing LOW PV OUTPUT?
    • R
      Rachel LongAug 27, 2025
      A 'LOW PV OUTPUT' status code on your Fronius Inverter can be due to the low level of insolation. However, if this code appears when there is sufficient insolation, contact your system engineer.
  • X
    xhesterAug 25, 2025
    What to do if Fronius Primo 8.2-1 Inverter shows Overcurrent (AC) error?
    • I
      ihoweAug 25, 2025
      The fault should rectify automatically. However, if the Fronius Inverter continuously displays this status code, you should notify a Fronius trained service engineer.

Fronius Primo 8.2-1 Specifications

General IconGeneral
AC Nominal Output Power8200 W
Frequency50 / 60 Hz
Dimensions (Height x Width x Depth)645 x 431 x 204 mm
Protection ClassIP65
Max. Apparent AC Power8.2 kVA
THD< 3%
DC Input Voltage Range200 - 800 V
Number of MPP Trackers2
DC ConnectionMC4
Nominal AC Voltage230 V
AC ConnectionScrew terminal
Operating Temperature Range-25°C - +60°C

Related product manuals