The Fronius Smart Meter IP is a bidirectional electricity meter which optimises
self-consumption and records a household's load curve. In conjunction with a
Fronius inverter or Fronius Datamanager 2.0 and a Fronius data interface, the
Fronius Smart Meter IP provides an overview of a user's own power consumption.
The meter measures the energy flow to the loads or to the public grid and for-
wards the information via the Modbus RTU/RS485- or TCP interface (LAN/
WLAN) to the Fronius inverter or the Fronius Datamanager 2.0.
Information on
the device
Technical data, markings and safety symbols are located on the Fronius Smart
Meter IP. These must NOT be removed or painted over. They warn against incor-
rect operation which can lead to serious injury and damage.
Symbols on the rating plate:
CE mark – confirms compliance with applicable EU directives and
regulations. The product has been tested by a specific notified body.
WEEE mark – waste electrical and electronic equipment must be
collected separately and recycled in an environmentally sound
manner in accordance with the European Directive and national law.
UKCA mark – confirms compliance with applicable UK directives and
regulations.
RCM mark – tested in accordance with the requirements of Australia
and New Zealand.
Intended use The Fronius Smart Meter IP is a fixed piece of equipment for public grids of
TN/TT systems and may only be used to measure loads and self-consumption.
The Fronius Smart Meter IP is required for systems with a battery storage system
and/or a Fronius Ohmpilot installed for communication between the individual
components.
The installation is carried out on an indoor DIN rail with corresponding back-up
fuses, which are adapted to the cable cross-sections of the copper conductors
and to the maximum current of the meter. The Fronius Smart Meter IP must only
be operated in accordance with the specifications in the enclosed documentation
and in accordance with local laws, regulations, provisions, standards and within
11