Fitting the
mounting brack-
et to metal sup-
ports
NOTE!
When mounted on metal supports, the inverter must not be exposed to rainwa-
ter or splashing water from the rear.
Provide suitable rainwater protection or splash water protection.
The mounting bracket must be securely screwed to at least four points.
1
Do not warp or
deform the
mounting brack-
et
IMPORTANT! When fitting the mounting bracket to the wall, ensure that the
mounting bracket does not become warped or deformed.
13
EN

Table of Contents

Other manuals for Fronius Symo 10.0-3-M

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius Symo 10.0-3-M and is the answer not in the manual?

Fronius Symo 10.0-3-M Specifications

General IconGeneral
Max. output current16.7 A
Max. input voltage1000 V
MPP voltage range200 - 800 V
Number of MPP trackers2
Protection classIP 65
AC voltage range150 - 280 V
Frequency50 / 60 Hz
THD< 3 %
AC Nominal Power10000 W
MPPT Voltage Range200 - 800 V
AC Frequency50 / 60 Hz
AC nominal output10000 W
Max. apparent AC power10000 VA
DC input voltage range200-1000 V
Operating Temperature-25°C to +60°C
Dimensions (W x H x D)725 x 510 x 225 mm
AC nominal voltage3 x 230 / 400 V