Measuring points
TSt 2200c
measuring points
The image below shows the measuring points on the secondary diodes.
The secondary diodes can be measured in the de-energised state with a multimeter in
diode test mode.
A voltage of approx. 0.15 V must be measured in the conducting direction of the diode
(1). Other measuring results indicate a defect in the diode, meaning it needs to be
replaced.
Temperature
sensor
X2
Cooling element /
transformer connection
X2 2-pin Microfit connector
Pin 1 Temperature signal Pin 2 + 5 V
A temperature-dependent resistance as per the table below must be measured between
pins 1 and 2 of the X2 connector.
Temp. [°C] R Nom [W] Temp. [°C] R Nom [W] Temp. [°C] R Nom [W]
0 32,650 35 6531 70 1752
5 25,388 40 5327 75 1481
10 19,900 45 4369 80 1258
15 15,708 50 3603 85 1072
13
EN