Service menu
General The service menu provides service technicians with detailed information about the
respective power source (e.g. firmware version, welding programs, arc time). In addition,
specific functions can be activated or deactivated and date and time settings can be
entered.
Opening/closing
the service menu
To open the service menu:
1
Press the two parameter selection
keys (arrow keys at the top) at the
same time.
2
Use the left-hand control dial to navig-
ate through the menu (for details, see
Description of the menu contents).
To close the service menu:
1
Press the two parameter selection
keys (arrow keys at the top) at the
same time.
Description of the
menu contents
Sequence Menu item (display) Description
1 Numerical value Firmware version
2 Numerical value Number of welding program database
3 Numerical value Number of the currently selected welding
program
4 Numerical value Arc time in hours
5 2nd Open menu level 2
To open menu level 2, press the two para-
meter selection keys (arrow keys at the top)
at the same time.
5.1 FdA Status of the motor calibration function
(AUTO/OFF)
To change the status, press the right-hand
control dial.
5.2 Fed Start motor calibration
To start motor calibration, press the torch
trigger or wire threading.
The following menu items are only available for TransSteel 3000c PULSE,
TransSteel 3500, TransSteel 3500c, TransSteel 4000 PULSE, TransSteel 5000 and
TransSteel 5000 PULSE if the "Easy Documentation" option is installed.
52