ESr 18 <PA>
A configuration memory is not supported, <PA> represents the error number
<PA> = 0 replace LSTMAG20 PC board
<PA> = 4 replace wirefeeder motor, replace device ID on wirefeeder motor
Cause:
Remedy:
ESr 22
The bootloader must be updated
Contact TechSupport International (TSI)
Cause:
Remedy:
------
Empty flag selected
Select valid flag
Cause:
Remedy:
UPdAtE
Software is being installed
Wait for installation to finish
Cause:
Remedy:
ELn 6
Error when writing calibration data
Repeat calibration procedure, replace wire-feed unit motor
Cause:
Remedy:
ELn 7
The connected control panel is not supported
Perform software update, connect supported control panel
Cause:
Remedy:
ELn 13
Illegal welding process change during welding
Do not make illegal welding process changes, acknowledge service code
Cause:
Remedy:
Err 11
5 V power supply on power module faulty
Replace LSTMAG20 PC board
Cause:
Remedy:
Err 12
15 V power supply on power module faulty
Replace LSTMAG20 PC board
Cause:
Remedy:
Err 51
Mains undervoltage: mains voltage has fallen below the tolerance range
Check mains voltage, replace LSTMAG20 PC board
Cause:
Remedy:
Err 52
Mains overvoltage, mains voltage has exceeded the tolerance range
Check mains voltage, replace LSTMAG20 PC board
Cause:
Remedy:
PFC 56
LSTMAG20 power module PC board has detected an overcurrent on the
PFC
Replace LSTMAG20 PC board
Cause:
Remedy:
PFC 57
Power module PC board has detected an overvoltage in the primary inter-
mediate circuit
Operate power source within the permitted voltage range
Cause:
Remedy:
16